Inteco Compression Load Cell

Kategoria: Compression Load Cells

INTECO COMPRESSION LOAD CELL

The load cell Inteco® represents a consistent enhancement to the wellknown PR 6201. With an additional load levels of
up to 75 t, higher accuracy classes (C6), high-quality stainless steel and output signal of 2 mV/V it has a wider range of possible application.
 

Features:
– range from 500 kg to 75 t
Output signal of 2 mV/V
–  Additional load levels 60t and 75t
Accuracy class (C6) from 3t
Higher corrosion resistance
Further development of the PR 6201 load cell
All accessories and installation kits of the PR 6201 load cell can still be used


ParameterDescriptionAbbr.D1/NC3C6Unit
Accuracy class     0.04 0.015 0,008 % Emax
Maximum capacity Highest limit of specified measuring range Emax See Ordering information table See Ordering information table See Ordering information table kg
Safe load limit Maximum load without irreversible damage Elim For 500 kg … 50 t: 150
For 60 t: 125
For 75 t: 100
For 500 kg … 50 t: 150
For 60 t: 125
For 75 t: 100
For 500 kg … 50 t: 150
For 60 t: 125
For 75 t: 100
% Emax
Destructive load Danger of mechanical destruction Ed For 500 kg … 50 t: >300
For 60 t: >250
For 75 t: >200
For 500 kg … 50 t: >300
For 60 t: >250
For 75 t: >200
For 500 kg … 50 t: >300
For 60 t: >250
For 75 t: >200
% Emax
Minimum LC verification Minimum load cell verification interval (vmin = Emax/Y)   See Accuracy classes and minimum verification interval, vmin table  See Accuracy classes and minimum verification interval, vmin table  See Accuracy classes and minimum verification interval, vmin table   
  For Emax = 500 kg Y 2,500 n.a. n.a.  
  For Emax = 1 t Y 5,000 n.a. n.a.  
  For Emax = 2 t Y 5,000 10,000 n.a  
  For Emax = 3 t … 75 t Y 5,000 14,000 3 t – 10 t: 14,000
>20 t: 20,000
 
Rated output Relative output at maximum capacity Cn 2     mV/V