INTECO COMPRESSION LOAD CELL
The load cell Inteco® represents a consistent enhancement to the wellknown PR 6201. With an additional load levels of
up to 75 t, higher accuracy classes (C6), high-quality stainless steel and output signal of 2 mV/V it has a wider range of possible application.
Features:
– range from 500 kg to 75 t
– Output signal of 2 mV/V
– Additional load levels 60t and 75t
– Accuracy class (C6) from 3t
– Higher corrosion resistance
– Further development of the PR 6201 load cell
– All accessories and installation kits of the PR 6201 load cell can still be used
| Parameter | Description | Abbr. | D1/N | C3 | C6 | Unit |
|---|---|---|---|---|---|---|
| Accuracy class | 0.04 | 0.015 | 0,008 | % Emax | ||
| Maximum capacity | Highest limit of specified measuring range | Emax | See Ordering information table | See Ordering information table | See Ordering information table | kg |
| Safe load limit | Maximum load without irreversible damage | Elim | For 500 kg … 50 t: 150 For 60 t: 125 For 75 t: 100 |
For 500 kg … 50 t: 150 For 60 t: 125 For 75 t: 100 |
For 500 kg … 50 t: 150 For 60 t: 125 For 75 t: 100 |
% Emax |
| Destructive load | Danger of mechanical destruction | Ed | For 500 kg … 50 t: >300 For 60 t: >250 For 75 t: >200 |
For 500 kg … 50 t: >300 For 60 t: >250 For 75 t: >200 |
For 500 kg … 50 t: >300 For 60 t: >250 For 75 t: >200 |
% Emax |
| Minimum LC verification | Minimum load cell verification interval (vmin = Emax/Y) | See Accuracy classes and minimum verification interval, vmin table | See Accuracy classes and minimum verification interval, vmin table | See Accuracy classes and minimum verification interval, vmin table | ||
| For Emax = 500 kg | Y | 2,500 | n.a. | n.a. | ||
| For Emax = 1 t | Y | 5,000 | n.a. | n.a. | ||
| For Emax = 2 t | Y | 5,000 | 10,000 | n.a | ||
| For Emax = 3 t … 75 t | Y | 5,000 | 14,000 | 3 t – 10 t: 14,000 >20 t: 20,000 |
||
| Rated output | Relative output at maximum capacity | Cn | 2 | mV/V |